Sign In | Join Free | My himfr.com
Home > Grundfos Pump Mechanical Seal >

891 SanLin Sewage Grundfos Pump Mechanical Seal GLF-SA-65L GLF-SA-65S

YUEMI
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 891 SanLin Sewage Grundfos Pump Mechanical Seal GLF-SA-65L GLF-SA-65S from wholesalers
     
    Buy cheap 891 SanLin Sewage Grundfos Pump Mechanical Seal GLF-SA-65L GLF-SA-65S from wholesalers
    • Buy cheap 891 SanLin Sewage Grundfos Pump Mechanical Seal GLF-SA-65L GLF-SA-65S from wholesalers
    • Buy cheap 891 SanLin Sewage Grundfos Pump Mechanical Seal GLF-SA-65L GLF-SA-65S from wholesalers
    • Buy cheap 891 SanLin Sewage Grundfos Pump Mechanical Seal GLF-SA-65L GLF-SA-65S from wholesalers

    891 SanLin Sewage Grundfos Pump Mechanical Seal GLF-SA-65L GLF-SA-65S

    Ask Lasest Price
    Brand Name : YUE MI
    Model Number : GLF-SA-60L GLF-SA-60S
    Certification : ISO SGS
    Price : US $ 1~99/PCS
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 1000/Set/Month
    Delivery Time : 2 word days
    • Product Details
    • Company Profile

    891 SanLin Sewage Grundfos Pump Mechanical Seal GLF-SA-65L GLF-SA-65S


    891 SanLin Sewage Grundfos Pump Mechanical Seal GLF-SA-65L GLF-SA-65S891 SanLin Sewage Grundfos Pump Mechanical Seal GLF-SA-65L GLF-SA-65S


    Product Description

    GLF-SA Mechanical Seal 32L-38S 38S-38L 38L-50S 50S-50L 50K-65S 65S-65L Water Pump Shaft Seal

    Description:
    Operating Range:
    Lower seal to suit for Grondfos Sarlin pumps.
    Replace Vulcan 42
    Size:25mm,32mm,38mm,50mm,65mm
    tructure: Single End
    Pressure: 1.6 MPa or less
    Temperature: - 20 ~ 120 ºC
    Linear Speed: 15 m/s or less
    Material:
    Rotary Ring: SiC/TC
    Stationary Ring: SiC/TC
    Elastomers: NBR/Vit
    Springs: SS304/SS316
    Metal Parts: 410S/SS304/SS316
    Mediums: water, oil, sewage, weak acid, weak alkali, and other weak corrosive mediums.
    Customization: Changes of materials for getting other operating parameters are possible. Contact us with your requirements.

    GR-SA Mechanical Seal for Sewage Pumps
    Structural Features: single end, multiple still springs with spring protection, balanced, independent direction of rotation, bolt transmission,
    non-cartridge seal. The springs are separated from the sealed mediums so that they will not be jammed. Multi spring structure makes
    sure the load on the sealing faces balanced. This seal component has a compact structure with easy installation and reliable performance.

    Scopes of Application: mainly used in sewage pumps, immersible pumps, paper pulp pumps and other rotary devices for industries such
    as city construction, mining, power plants and sewage treatment. This component can work as an alternative to Gorman-Rupp and
    Grondfos original seal product GR-SA or replacing Type 891 mechanical seal.

    Technical Parameters

    Temperature-30℃~+200℃
    pressure≤1.2Mp a
    Speed≤10m/s
    Mediumsewage

    Materials

    Rotary Ring

    SiC/VIT

    Stationary Ring

    SiC/VIT

    SpringSUS304/SUS316
    Stationary SeatSUS304/SUS316
    Secondary Seal

    VITON/EPDM

    Rotary Ring HolderSUS304/SUS316



    Preperation:
    1. Shaft Outside Diameter is within tolerance +-0.05mm
    2. Shaft run out <0.1mm
    3. Shaf end float <0.13mm
    4, No sharp edges on the shaft over the o ring
    Note:
    During the installation,don't scratch or damage the o ring.lf anything is damaged,please contactwith Us to replace a new one.
    Installation in strucstions:
    1. The full set of cartridge seal is cleaned and exactly passed leakage examine before sale.Inorder to avoid damage,don't disassemble and clean the parts again before fixing.

    2 The fitting allowance between the seal and shaft is dl h6 0.8,and there should be leading-inedge at the end of shaft.The outside diameter of shaft at the position of screw should be 01 0.2mm smaller,resisting the screw over-tighten.Lubricate the shaft with oil

    3. Place the cartridge seal into the pump chamber,then:
    A: Tighter four screw bolts of flanges,ensuring the medium leading in hole"G"at the top Position
    B : Tighter four set screws and position the shaft sleeve on the shaft.
    C: Remove four gauge plates.Please keep them and they wil be used in future installation and
    disassemble.
    D: Connect the medium lead_in pipe with hole"G"in order to flush away the friction heat and
    flushing the seal chamber when pump running.
    Note:
    ter complete the installation,turning the shaft by hand to check for the rotationi he shat could not rotate smoothily,seal had been improperly installed.


    We would like lo sincerely ooperale with Clients to supply high qually products and senice We beleve in establishing a long:erm cooperalive relalionshipis lhe key to suceess

    891 SanLin Sewage Grundfos Pump Mechanical Seal GLF-SA-65L GLF-SA-65S












































    Quality 891 SanLin Sewage Grundfos Pump Mechanical Seal GLF-SA-65L GLF-SA-65S for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: YUEMI
    *Subject:
    *Message:
    Characters Remaining: (0/3000)